§ 24A-15. Surfaces.  


Latest version.
  • It shall be unlawful to operate any parking lot unless it shall be graded to drain properly and shall be paved with one of the following materials:

    (a)

    Five (5) inches of gravel with one course penetration.

    (b)

    Three (3) inches of gravel with one and one-half (1½) inches of hot mix asphaltic concrete.

    (c)

    Five (5) inches two thousand five hundred (2,500) P.S.I. concrete with #3 bars on twenty-four (24) inch centers or six (6) inch by six (6) inch wire mesh reinforcement.

    (d)

    Six (6) inch lime stabilized base with one-half (½) inch Slurry Seal.

    (e)

    Six (6) inch lime stabilized base with two (2) course penetration.

(Ord. No. 2577, § 5, 9-20-73)