§ 8B-19. Amendments, additions, and deletions to the 2015 edition of the International Mechanical Code.  


Latest version.
  • (a)

    Amendments included in this section are intended to be specific code provisions. If there is a conflict between a provision in the published 2015 International Mechanical Code and this section, the specific provisions of this section shall control.

    (b)

    The following table contains the local amendments to the 2015 edition of the International Mechanical Code, which is modified as set forth herein:

    (1)

    When identified by the letter "R," the corresponding section of the 2015 International Mechanical Code is deleted in its entirety and replaced by the local amendment as set forth in Column 3 of the table below.

    (2)

    When identified by the letter "S," the corresponding section of the 2015 International Mechanical Code is supplemented by the additional provision as set forth in Column 3 of the table below.

    (3)

    When identified by the letter "M," the corresponding section of the 2015 International Mechanical Code is modified by amending the language of the provision to read as set forth in Column 3 of the table below.

    Table Legend:

    Column 1: Item Reference Number

    Column 2: Related code section/caption

    Column 3: Amended code provision

    Column 4: "R" - 2015 International Mechanical Code section is replaced by the provision in Column 3; "S" - 2015 International Mechanical Code section is supplemented by the provision in Column 3; "M" - 2015 International Mechanical Code section is modified by the provision in Column 3.

    TABLE OF LOCAL AMENDMENTS TO THE 2015 INTERNATIONAL MECHANICAL CODE

    1 IMC 103
    Department of mechanical inspections
    Wherever the term "department of mechanical inspection" it shall mean the department of inspections.
    M
    2 IMC 106
    Permits
    Permits that have been approved for which payment has not been received within 14 days may be cancelled.
    S
    3 IMC 106.5
    Fees
    Refer to Section 8B-3 of Chapter 8B of The Land Development Code of The City of Irving, Texas.
    R
    4 IMC 109
    Means of appeal
    Refer to Section 8B-4 of Chapter 8B of The Land Development Code of The City of Irving, Texas.
    R
    5 IMC 306.3
    Appliances in attics
    Walkways in attics shall be rated as floors. When appliances are installed in attics, access shall be by one of the following methods:
    a. A permanent stair,
    b. A pull-down stair with a minimum 300 pound capacity,
    c. An access door from an upper floor level, or
    S
    6 IMC 306.5
    Equipment and appliances on roofs or elevated structures
    A permanent interior or exterior ladder shall be provided to access equipment or appliances on roofs or elevated structures where personnel will have to climb higher than 16 feet. Exterior ladders need not extend closer than 12 feet to the finish grade or floor.
    S
    7 IMC 306.5.1
    Sloped roofs
    Where appliances or equipment is installed on a roof having a slope of 3 units vertical in 12 units horizontal or greater, a catwalk of at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance or equipment.
    S
    8 IMC 501.3
    Exhaust discharge
    Toilet room exhaust ducts may terminate in a warehouse or shop area when infiltration of outside air is present.
    S
    9 IMC 504.4
    Exhaust installation
    Clothes dryer exhaust duct size shall not be reduced along its developed length or at termination.
    S
    10 IMC 1002
    Water heaters
    On or after February 15, 2009, water heaters with storage tanks shall not be installed in attics, unless such water heater was installed prior to such date. This section does not prohibit the replacement of water heaters with storage tanks in attics if such water heaters were legally permitted and installed prior to February 15, 2009.
    S

     

(Ord. No. 2015-9748, § 2, 12-10-15)